Η αποστολή του λόγω βάρους γίνεται με παλέτα. Απαιτείται σύνδεση του από ηλεκτρολόγο σύμφωνα με τις οδηγίες χρήσης και σύνδεσης. ● High frequency on-line double conversion technology● Advanced DSP and 3-level technology● Output power factor 1.0● Active power factor correction (APFC), input power factor up to 0.99● High efficiency 95% (up to 98% in ECO mode)● Advanced digital parallel technology● Wide input voltage range (110 ~ 288 Vac) and frequency range (40 ~ 70 Hz)● 50 / 60 Hz frequency auto sensing● Two modes of frequency conversion: 50 Hz input / 60 Hz output or 60 Hz input / 50 Hz output● Dual-input design, supporting independent bypass● Flexible battery configuration (settable 16 – 20 pcs batteries)● Digitally controlled charger● High charging current available (Max. 12 A)● Charging voltage and current configured by demands● Linear derating in low voltage input reducing battery discharging times, extending the service life of battery● Intelligent battery management, automatic floating / equalizing charge control, charger dormancy control, increasing battery life by 50%● Ability to switch on the UPS with batteries● Settable delayed start time when mains power is restored, reducing the impact on power grid or generator● Fan speed varies intelligently with temperature, reducing noise and extending its service life● Equipped with self-aging function● Compact internal layout, miniaturized the complete unit for small footprint● LCD+LED display, multi-functional keys operation, friendly human-machine interface● Powerful background software for parameters configuration● Advanced multi-platform communications: RS232, USB, RS485, SNMP and dry contacts communication interfaces● Effective software and hardware protection function, robust self-diagnostic function, and abundant event log for check● RS232 and smart card slot includedMODELNG-UPS-ON6Capacity6 kVA / 6000 WINPUTInput wiringSingle-phase three-wire (1Φ + N + PE)Rated voltage208 / 220 / 230 / 240 VacVoltage range 110 ~ 176 Vac (linear derating between 50% and 100% load);176 ~ 288 Vac (no derating)Rated frequency50 / 60 Hz (auto-sensing)Frequency range40 ~ 70 HzPower factor≥0.99Bypass voltage range- 40% ~ +15% (settable)Total harmonic distortion (THDi)≤5%OUTPUTOutput wiringSingle-phase three-wire (1Φ + N + PE)Rated voltage208 (PF=0.9) / 220 / 230 / 240 VacVoltage regulation±1%FrequencySynchronized to bypass in mains mode; 50 / 60 Hz ± 0.1% Hz in battery modeWaveformSinusoidalPower factor1Total harmonic distortion (THDv)≤1% (linear load);≤4% (non-linear load)Crest factor3:1Overload 105% ~ 110% for 10 min, 110% ~ 125% for 1 min,126% ~ 150% for 30 sBATTERIES DC voltage192 Vdc (192 ~ 240 Vdc settable) Number of battery16 pcs Inbuilt battery (standard model)12 V / 9 Ah × 16 Charging currentModel: 1 A;Recharge timeStandard model: 90% capacity restored in 8 hours;SYSTEMEfficiency≥ 94% at 100% load, max. 95% at 60% load, ≥ 98% in ECO modeTransfer time0 msProtectionsShort-circuit, overload, overtemperature, battery low voltage, overvoltage, undervoltage and fan failureMax. number of parallel connections4CommunicationsRS232 (standard), USB / RS485 / dry contacts / SNMP / battery temperature compensation (optional)DisplayLCD + LEDOTHERSOperating temperature0℃ ~ 40℃Storage temperature-25℃ ~ 55℃ (without battery)Relative humidity0 ~ 95% (non-condensing)Altitude≤ 1000 m, derating 1% for each additional 100 mIP ratingIP 20Noise level at 1 m≤55 dBDimensions (W × D × H) (mm)191 × 465 × 711 (S), 191 × 465 × 350 (H)Packaged dimensions (W × D × H) (mm)310 × 654 × 941 (S), 318 × 595 × 475 (H)Net weight (kg)53 (S), 14.5 (H)Gross weight (kg)61 (S), 16 (H)